Incl. VATExcl. VAT
Sale

Siemens N 141/02 – 5WG1141-1AB02 *Refurbished*

£579.00 Excl. VAT £189.99 Excl. VAT

Product Code – 5WG1141-1AB02

Product Datasheet – SIEMENS – 5WG11411AB02

Estimated Delivery – 1-3 Working days.

You’ll receive a shipping confirmation once your order has been dispatched, confirming your delivery date and tracking.

USE CODE: DGW05 – For 5% off when you buy 2 or more N141/02’s.

14 in stock

SKU: 01/03/SBT/0028 Categories: , , Tag:
Description

 

KNX/DALI Gateway – REFURBISHED

PLEASE NOTE THIS ITEM IS REFURBISHED – THIS ITEM HAS BEEN USED.  ALL OUR REFURBISHED PRODUCTS ARE TESTED TO CHECK THE ITEM IS IN GOOD WORKING CONDITION.  THIS ITEM MAY SHOW SIGNS OF WEAR BUT DOESN’T AFFECT THE FUNCTIONALITY OF THE DEVICE.

 

These KNX/DALI Gateways are KNX devices with one independent DALI interfaces. Up to 64 DALI actuators (e.g. ECG with DALI interface).

DALI (Digital Addressable Lighting Interface) is a bidirectional communications interface to IEC 62386, whose specification was chosen by manufacturers for electronic ballasts. It not only receives, for example, switching and dimming commands, but also transmits status information such as failure of an illuminant or reporting of a detected error in the ballast. The KNX/DALI Gateways enable communication with up to 64 DALI actuators per channel. These can be connected and dimmed in groups. They also make it possible to record and transfer DALI status and error messages. An individual name, a group, parameter and scenes are assigned to individual DALI ECG during commissioning with the ETS (Engineering Tool Software). DALI sensors are also assigned to groups in the ETS (for this, go to the application program description).

The integrated power supply unit supplies the gateway electronics and generates the DALI bus voltage. It facilitates operation of the gateway and direct switching and dimming of all DALI ECG’s controlled via the DALI interface, even if the gateway has still not been operated with the ETS or if communication via KNX is interrupted.

The devices have a voltage detector during initialization, which detects whether a voltage has been applied to the DALI terminals incorrectly.

The DALI power supply feeds ECG’S; verify that the maximum permissible current drain by all connected DALI devices is not exceeded.

Please note;  The firmware may need updating due to this being a discontinued product.

 

Additional Information
Weight 0.228 kg
Dimensions 11.30 × 11.30 × 9 cm
Manufacturer

Siemens

Type

,